Application Area
Low-pressure air tests in wastewater and stormwater lines are used for temporarily sealing the line and for isolation procedures for inspection purposes. Options are available for diameters between 300 mm and 1100 mm.Technical Usage Notes
- The maximum operating pressure of 1.5 bar must not be exceeded.
- One of the connection outlets can be used for inflation, and the other for pressure measurement.
- The pipe diameter must be within the range in the table for the selected size.
- During the test, pressure changes should be monitored from the gauge.
Technical Dimensions Table
| Nominal Size | Min. Pipe Diameter (mm) | Max. Pipe Diameter (mm) | Max. Working Pressure (bar) | Product Diameter (mm) | Product Length (mm) | Bypass Diameter (inch) | Product Weight (kg) |
|---|---|---|---|---|---|---|---|
| 300 - 400 | 300 | 400 | 1,5 | 280 | 250 | 2 x 1/4" | 2 |
| 400 - 500 | 400 | 500 | 1,5 | 380 | 250 | 2 x 1/4" | 3 |
| 500 - 600 | 500 | 600 | 1,5 | 480 | 250 | 2 x 1/4" | 4 |
| 600 - 700 | 600 | 700 | 1,5 | 580 | 250 | 2 x 1/4" | 5 |
| 700 - 800 | 700 | 800 | 1,5 | 680 | 250 | 2 x 1/4" | 6 |
| 800 - 900 | 800 | 900 | 1,5 | 780 | 250 | 2 x 1/4" | 7 |
| 900 - 1100 | 900 | 1100 | 1,5 | 880 | 250 | 2 x 1/4" | 8 |
Low Pressure Test Plug get a quote
Low Pressure Test Plug for
Get a technical quote.
Contact us for model selection suitable for your project. We guarantee a detailed technical response within 48 hours.