Application Area
It is used for leak-tightness tests in small-diameter drainage, wastewater, and plumbing lines, as well as for temporarily shutting off the line during maintenance. Options are available for nominal sizes between 1 1/2" and 6"; the maximum back pressure ranges from 0.5 to 2 bar depending on the size.Technical Usage Notes
- The maximum back pressure value, which varies by size, must not be exceeded.
- The tightening process must be carried out so that the gasket seats evenly against the pipe wall.
- The gasket surfaces must be clean and undamaged.
- Double-seal plugs can be produced to order.
Technical Dimensions Table
| Nominal Size | Min. Pipe Diameter (mm) | Max. Pipe Diameter (mm) | Max. Back Pressure (bar) | Bypass Diameter (inch) |
|---|---|---|---|---|
| 1 1/2" | 36 | 50 | 2 | 1/2" |
| 2" | 50 | 60 | 2 | 1/2" |
| 2 1/2" | 60 | 75 | 2 | 1/2" |
| 3" | 70 | 85 | 1,2 | 1/2" |
| 3 1/2" | 85 | 100 | 1 | 1/2" |
| 4" | 95 | 105 | 0,6 | 1/2" |
| 4 1/2" | 110 | 125 | 0,6 | 1/2" |
| 5" | 120 | 140 | 0,6 | 1/2" |
| 6" | 145 | 160 | 0,5 | 1/2" |
Double-seal plugs can be produced to order.